BiblCit: Jiroušek, Ondřej ; Jandejsek, Ivan ; Vavřík, Daniel. Evaluation of strain field in microstructures using micro-CT and digital volume correlation. Journal of Instrumentation, 2011, Roč. 6, January, s. 1-5. ISSN 1748-0221.\nhttp://iopscience.iop.org/1748-0221/focus/extra.proc10
BiblCitZdrD: Journal of Instrumentation, 2011, Roč. 6, January, s. 1-5
ISBN_ISSN_ZdrDok: 1748-0221
ZemeZverejneni: GB
Jazyk: eng
PocStran: 5
ImpFaktor: 3.148
ProjektyCEP: GAP105/10/2305:GA ČR
VyzZamer: CEZ:AV0Z20710524
OrigNazev: Evaluation of strain field in microstructures using micro-CT and digital volume correlation
KlicSlova: inspection with x-rays - overall mechanics design - pixelated detectors and associated VLSI electronics
AnotaceOrig: X-ray digital micro-tomography was employed for precise strain measurement which is essential for evaluation of the experiments with small samples of trabecular bone. X-ray Digital Volumetric Correlation (DVC) method was used to identify the three-dimensional strain field in loaded complex microstructure. DVC relies on tracking selected sample points within the threedimensional image data throughout the sequence of captured projections. In this study an improved DVC method is applied for evaluation of the strain field in trabecular bone sample subjected to compressive loading. The deformed sample was tomographically scanned using micro-focus X-ray tube and the single-photon counting silicon pixel detector Medipix2.
AnotaceCz:
KodOborRIV: JJ
Konference: International workshop on radiation imaging detectors /12./. Cambridge, 12.07.2010-15.07.2010
VlastnikZaznamu: UTAM-F
OdevzdaniDoRIV: 1
RokVydani: 2011
RokSberu: 2011
PocetCitaci: 0
Sysno: 354592
ZpZverejneni: J
AutoriVsichni: Jiroušek, Ondřej - Jandejsek, Ivan - Vavřík, Daniel
AutoriAV: Jiroušek, Ondřej - Jandejsek, Ivan - Vavřík, Daniel
AutoriVsichniPocet: 3
AutoriAVPocet: 3
BiblCit: Jiroušek, Ondřej ; Jandejsek, Ivan ; Vavřík, Daniel. Evaluation of strain field in microstructures using micro-CT and digital volume correlation. Journal of Instrumentation, 2011, Roč. 6, January, s. 1-5. ISSN 1748-0221.\nhttp://iopscience.iop.org/1748-0221/focus/extra.proc10
BiblCitZdrD: Journal of Instrumentation, 2011, Roč. 6, January, s. 1-5
ISBN_ISSN_ZdrDok: 1748-0221
ZemeZverejneni: GB
Jazyk: eng
PocStran: 5
ImpFaktor: 3.148
ProjektyCEP: GAP105/10/2305:GA ČR
VyzZamer: CEZ:AV0Z20710524
OrigNazev: Evaluation of strain field in microstructures using micro-CT and digital volume correlation
KlicSlova: inspection with x-rays - overall mechanics design - pixelated detectors and associated VLSI electronics
AnotaceOrig: X-ray digital micro-tomography was employed for precise strain measurement which is essential for evaluation of the experiments with small samples of trabecular bone. X-ray Digital Volumetric Correlation (DVC) method was used to identify the three-dimensional strain field in loaded complex microstructure. DVC relies on tracking selected sample points within the threedimensional image data throughout the sequence of captured projections. In this study an improved DVC method is applied for evaluation of the strain field in trabecular bone sample subjected to compressive loading. The deformed sample was tomographically scanned using micro-focus X-ray tube and the single-photon counting silicon pixel detector Medipix2.